Process Electric Heaters
Process Heat & Control Systems | CEM/Bar Tubular Heaters | Pipe Plug Immersion Heaters | Flanged Immersion Heaters | Circulation Heaters | Over-The-Side Immersion Heaters | Boiler & Water Heaters | Pipe Insert Heaters | Quartz Immersion Heaters | Bottom Mount Immersion Heaters | Dishwasher Heaters | Sink Sanitizer Immersion Heaters | Drum Heaters | Process Air Heaters | Enclosure Heaters | Finned Tubular Heaters
PROCESS AIR HEATERS

Installed in forced air ducts, these units supply constant heat for industrial processes requiring air temperatures up to 750°F / 400°C. Construction features include heavy gauge mounting flange, insulated terminal enclosure and easily replaced heating elements. Typical uses include forced air dryers, core drying, heat treating, annealing and other high temperature applications.
Process Air Heater type CDH

Guidelines

  • Maximum Sheath Temperature: 1150°F/620°C
  • Maximum Outlet Air Temperature: The guideline is based on 22 watts per square inch.

    Air Velocity:
    360 feet/minute
    540 feet/minute
    960 feet/minute
    Maximum Outlet
    Air Temperature:

    650°F/340°C
    700°F/370°C
    750°F/400°C
    Unit should not be energized in air energized with a velocity less than 60FPM.
    A B D X VOLTS
    3
    PHASE
    kw No. of
    Element
    No. of
    Mtg. Hole
    Catalog
    Number
    5-5/8 20-3/8 4 2-1/2 240 6 6 10 CDH-6B
    7-5/8 20-3/8 6 3-1/2 480 12 12 10 CDH-12A
    7-5/8 20-3/8 6 3-1/2 240 12 12 10 CDH-12B
    9-5/8 20-3/8 8 3 480 18 18 12 CDH-18B
    11-5/8 20-3/8 10 2-3/4 480 24 24 14 CDH-24B
    13-5/8 20-3/8 12 3-1/4 480 30 30 14 CDH-30B
    15-5/8 20-3/8 14 3-1/4 480 36 36 14 CDH-36B
    17-5/8 20-3/8 16 4-1/4 480 42 42 14 CDH-42B
    19-5/8 20-3/8 18 4-3/4 480 48 48 14 CDH-48B
    21-5/8 20-3/8 20 5-1/4 480 54 54 14 CDH-54B
    23-5/8 20-3/8 22 5-3/4 480 60 60 14 CDH-60B
    For 240V, 3ø, add suffix "A"  For 480V 3ø, add suffix "B"
    EXAMPLE for 240V: ODH-6A  Specify special ratings

  • HIGH TEMPERATURE PROCESS AIR HEATERS

    Type HPA High Temperature Process Air Heaters Type HPA

    High Temperature Process Air Heaters provide process temperatures up to 1200°F/ 650°C for many oven and forced air applications. Typical applications are recirculating ovens, converting ovens from gas or oil combustion, drying or curing ovens, heat treating, annealing and dehumidification.

    Guidelines

  • Maximum Sheath Temperature: 1500°F/815°C
  • Maximum Process Temperature: This guideline is based on 20 watts per square inch.

    Air Velocity:
    Maximum Outlet
    Air Temperature:
    240 feet/minute
    540 feet/minute
    960 feet/minute
    1500 feet/minute
    2160 feet/minute
    1050°F/565°C
    1100°F/595°C
    1150°F/620°C
    1200°F/650°C
    1200°F/650°C