BAND HEATERS
Introduction | High Temp Mineral Insulated Band Heaters | Aluminum Shoe Band Heaters | Ceramic Band Heaters | Mica Band Heaters
CERAMIC INSULATED BAND HEATERS

Air Cooled Band Heaters
A perforated rather than insulated shroud with a cowl, plenum and blower is designed for use on plastic extension equipment where some processes generate excessive heat from pressure. Air Cooled Band Heaters When a predetermined temperature is exceeded, the blower will engage, cooling the process. Air Cooled Band Heaters
Further Information Under "Extruder Products" Section


Specifications:
Resistance Tolerance: NEMA Standard plus 10%,
   Minus 5%
Wattage Tolerance: NEMA Standard pius 5%,
   Minus 10%
Cold Resistance: 12% lower than hot resistance
Maximum Votts: 600
Maximum Amperage: 25
Maximum Waft Density: 45 watts/sq. in.
Minimum Width: 1"
Maximum ID.: 18" full band; 32" halt band
Maximum Width:
Minimum ID.: 2"
Minimum ID.: Double Insulated: 4"

¼"Insulation 2x I.D.
½"Insulation 2x I.D.
  Below 6" I.D. 6" I.D. & Above
Maxi-Insulation N/A 1½ x I.D.

Standard Width Increments: ½"
Standard Gap when Tightened: ½"
Thickness w/¼" Insulation: 5/8"
Thickness w/½" Insulation: ¾"

Ceramic heaters cam be manufactured in flat design for use as a strip heater, radiant heater or without shroud for use as a furnace element.
Maintenance and Trouble Shooting for Prolonged Heater Life:
  1. Regulate Voltage. A 10% variation in voltage results in a 20% variation in power.
  2. The cylinder must be clean and smooth for efficient heat transfer.
  3. When attaching the lead wires to the terminals, excessive turning pressure can cause breakage of the terminal resistance wire.
  4. A ½" gap should be maintained at the opening when operating. Retightening is not normally required, however, if the operating temperature is changed, the flange bolt should be checked.
  5. Oil, plastic, dirt, etc., should not be allowed to accumulate on the heaters.
  6. Select a heater to match the diameter of the cylinder.
  7. Match the heaters as closely as possible to the actual load requirement.
Ordering Information
Specify:
  • Catalog number if available
  • Inside diameter
  • Width
  • Watts and Volts
  • If 2 piece, watts and volts each half
  • Type of termination
  • Modifications or options
  • Sketch or drawing if necessary