BAND HEATERS
Introduction | High Temp Mineral Insulated Band Heaters | Aluminum Shoe Band Heaters | Ceramic Band Heaters | Mica Band Heaters
CERAMIC INSULATED BAND HEATERS

 


Quick Disconnect High Temperature Plugs

Quick Disconnect High Temperature Plugs High Temperature Quick Disconnects are available on any construction or clamping variation. P1 and P2 quick disconnect plug assemblies are highly recommended and should be used whenever possible. The combination of plug and cup assembly along with armor cable covered leads eliminate all live exposed terminals or wiring that can be a potential hazard to employees or machinery. The P1 plug assembly is available with a straight or right-angle plug. The P2 plug assembly has a lower profile and is available with a straight plug only.

To simplify installation, band heaters with P1 or P2 plug assemblies can be supplied pre-wired, using high temperature lead wire protected with armor cable—specify length.

Max. Temp.: 572°F (3OO°C)
Max. Amps: 16
Max. Volts: 25OVAC
Quick Disconnect High Temperature Plugs

General Purpose Terminal Boxes

Standard Box


Built-In Bracket - Standard
Built-In Bracket - Standard
The Built-ln Bracket is the basic design most often specified by OEM's and processors. The standard screw used a ¼"-20. It is available with all types of insulation, construction styles, or termination variations.

The Built-In Bracket can also be supplied with a spring loaded screw. The spring loaded clamp aids in absorbing thermal expansion.

Limitations
Min. ID: 2" (50.8 mm)
Min. Width: 1" (25.4 mm)

Latch and Trunion
Latch and Trunion
The spring loaded Latch and Trunion clamping system is ideal for bands over 12" in diameter to absorb thermal expansion and facilitate installation 0n large bands.

The Latch and Trunion clamping system is available with all types of insulation, construction styles, or termination variations.

Limitations
Min. ID 4" (101.6 mm)
Min. Width: 1" (25.4 mm)

Low Profile Box
Bent-Up Flange (Ears)
Bent-Up Flange (Ears)
The Bent-Up Flange (Ears) is available with all types of insulation, construction styles, or termination variations.

Limitations
Min. ID: 2" (50.8 mm)
Min. Width: 1" (25.4 mm)